- Home
- ยป
- Product Range
- »
- Power Quality Analyzer
Power Quality Analyzer
Fluke 1738 Advanced Power Logger
Product Brochure
Type of Data Logger | Wireless Data Logger, Digital Data Logger |
No. of Channels | Dual Channel |
Voltage Range | 100 V to 500 V |
Mains power frequency | 50/60 Hz +/-15 % |
Charging time | Less than 6 hours |
Battery | Li-ion 3.7 V, 9.25 Wh, customer-replaceable |
Maximum no load consumption | Less than 0.3 W |
Averaging interval | 10 min |
We are one of the leading wholesale traders of Fluke 1738 Advanced Power Logger.
Features:-
Key measurements Automatically capture and log voltage, current, power, harmonics and associated power quality values.
Fluke Connect compatible* View data locally on the instrument, via Fluke Connect mobile app and desktop software or through your facilities WiFi infrastructure.
Convenient instrument powering Power instrument directly from the measured circuit.
Highest safety rating in the industry 600 V CATIV/1000 V CATIII rated for use at the service entrance and downstream.
Measure all three phases and neutral With included 4 flexible current probes.
Comprehensive logging More than 20 separate logging sessions can be stored on the instruments. In fact, all measured values are automatically logged so you never lose measurement trends. They can even be reviewed during logging sessions and before downloading for real-time analysis.
Capture dips swells, and inrush currents Include event waveform snapshot and high-resolution RMS profile, along with a date, timestamp and severity to help pinpoint potential root causes of power quality issues.
Power Quality Health Summary Summarizes the most important power quality health parameters to provide fast insight into overall electrical system health, indicating whether more detailed analysis and reporting should be done.
Bright, color touch screen Perform convenient in-the-field analysis and data checks with the full graphical display.
Optimized user interface Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function.
Complete "in-the-field" setup through the front panel or Fluke Connect App No need to return to the workshop for download and setup or to take a computer to the electrical panel.
Fully integrated logging Connect other Fluke Connect devices to the Fluke 1738 to simultaneously log up to two other measurement parameters, virtually any parameter available on a Fluke Connect wireless digital multimeter.*
Fluke 1736 Power Logger
Product Brochure
Type of Data Logger | Wireless Data Logger, Digital Data Logger |
No. of Channels | 4 Channel |
Operating Temperature | -10 C to +50 C |
Bandwidth | 42.5 Hz - 3.5 kHz |
Measurement category | 1000 V CAT III/600 V CAT IV |
Storage altitude | 12,000 m |
Instrument Dimension | 19.8 cm x 16.7 cm x 5.5 cm |
Features:-
- Key measurements
- Automatically capture and log voltage, current, power, harmonics and associated power quality values.
- Fluke Connect compatible* View data locally on the instrument or via Fluke Connect mobile app and desktop software.
- Convenient instrument poweringPower instrument directly from the measured circuit.
- Highest safety rating in the industry 600 V CATIV/1000 V CATIII rated for use at the service entrance and downstream.
- Measure all three phases and neutral With included 4 flexible current probes.
- Comprehensive logging More than 20 separate logging sessions can be stored on the instruments. In fact, all measured values are automatically logged so you never loose measurement trends. They can even be reviewed during logging sessions and before downloading for real-time analysis.
- Capture dips, swells, and inrush currentsIncludes event waveform snapshot and high resolution RMS profile, along with the date, timestamp and severity to help pinpoint potential root causes of power quality issues.
- Bright, color touch screen Perform convenient in-the-field analysis and data checks with the full graphical display.
- Optimized user interface Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function.
- Complete "in-the-field" setup through the front panel or Fluke Connect App No need to return to the workshop for download nd setup or to take a computer to the electrical panel.
- Energy Analyze Plus application software
- Download and analyze every detail of energy consumption and power quality state of health with our automated reporting.
Fluke 438-II Power Quality and Motor Analyzer
Product Brochure
Model | Fluke 438-II |
Frequency | 50/60 Hz |
Application | Industrial Use |
Brand | Fluke |
Waveform capture function | Captures 100/120 cycles |
Safety Rating | 600 V CAT IV/1000 V CAT III |
We are one of the leading wholesale traders of Fluke 438-II Power Quality and Motor Analyzer.
Features
The ideal portable motor analysis test tool, the 438-II can help locate, predict, prevent, and troubleshoot power quality problems in three-phase and single-phase power distribution systems, while giving technicians the mechanical and electrical information they need to effectively evaluate motor performance.
- Measure key parameters like speed, torque and mechanical power without mechanical sensor all while the motor is in service simply by using three-phase input measurements
- Calculate Mechanical Power and Efficiency without the need of mechanical sensors
- Automatically calculate motor derating according to NEMA/IEC guidelines
- Measure electrical power parameters such as voltage, current, power, apparent power, power factor, harmonic distortion and unbalance to identify characteristics that impact motor efficiency
- PowerWave data technology captures fast RMS data, and shows half-cycle averages and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.)
- Identify power quality issues such as dips, swells, transients, harmonics and unbalance
- Waveform capture function captures 100/120 cycles (50/60 Hz) of each event detected event, in all modes, without set-up
- Automatic transient mode captures waveform data at 200 kS/s on all phases simultaneously up to 6 kV
- Fluke Connect compatible* - view data locally on the instrument, via Fluke Connect mobile app and PowerLog 430-II desktop software
- Highest safety rating in the industry 600 V CATIV/1000 V CATIII rated for use at the service entrance
Three-Phase Power Logger - Fluke 1735
Product Brochure
Model | Fluke 1735 |
Brand | FLUKE |
Memory | 4 MB Flash memory, 3.5 MB for measuring data |
Warranty | 1 Year |
Dimensions | 240 mm x 180 mm x 110 mm |
Weight | 1.7 kg, including battery |
Line frequency | 50 Hz or 60 Hz |
Display | 320 x 240 Pixel |
Features:
- Record power and associated parameters for up to 45 days
- Monitor maximum power demand over user-defined averaging periods
- Prove the benefit of efficiency improvements with energy consumption tests
- Measure harmonic distortion caused by electronic loads
- Improve reliability by capturing voltage dips and swells from load switching
- Easily confirm instrument setup with the color display of waveforms and trends
- Measure all three phases and neutral with included 4 flexible current probes
- View graphs and generate reports with included Power Log software
- Compact, rugged design with the IP65 case, 600 V CATIII and the two-year warranty
Applications:-
- Load studies - verify electrical system capacity before adding loads
- Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices
- Harmonics measurements - uncover harmonic issues that can damage or disrupt critical equipment
- Voltage event capture - monitor for dips and swells that cause spurious resets or nuisance circuit breaker tripping
Fluke 435 Series II Power Quality and Energy Analyzer
Product Brochure
Brand | Fluke |
Operating Temperature | 0 C ~ +40 C |
Storage Temperature | -20 C ~ +60 C |
Maximum input voltage | 1000 Vrms |
Nominal voltage range Selectable | 1 V to 1000 V |
Output cable length | 2.5 meters RG58 |
Current range | 6000 A AC RMS |
Applications
- PowerWave data capture – capture fast RMS values to see every waveform so you can determine how the voltage, current and frequency values are interacting
- Power inverter efficiency – Power inverter efficiency
- Energy monetization – calculate the fiscal cost of energy waste due to poor power quality
- Energy assessment – quantify the before and after installation improvements in energy consumption to justify energy saving devices
- Frontline troubleshooting – quickly diagnose problems on-screen to get your operation back online
- Predictive maintenance – detect and prevent power quality issues before they cause downtime
- Long-term analysis – uncover hard-to-find or intermittent issues
- Load studies – verify electrical system capacity before adding loads
Fluke 437 Series II 400Hz Power Quality and Energy Analyzer
Product Brochure
Brand | Fluke |
Maximum input voltage | 1000 Vrms |
Max peak measurement voltage | 6 kV |
Bandwidth | Up to 100 kHz for transient mode |
Nominal voltage range Selectable | 1 V to 1000 V |
Probe cable bend radius | 38.1 mm |
Probe cable diameter | 12.4 mm |
Applications:-
- 400 Hz measurement – capture power quality measurements for avionic and military power systems.
- PowerWave data capture – capture fast RMS values to see every waveform so you can determine how the voltage, current, and frequency values are interacting.
- Power inverter efficiency – measure both ac power and dc power, in and out, to monitor the efficiency of inverters.
- Energy monetization – calculate the fiscal cost of energy waste due to poor power quality.
- Energy assessment– quantify the before and after installation improvements in energy consumption to justify energy saving devices.
- Frontline troubleshooting – quickly diagnose problems on-screen to get your operation back online.
- Predictive maintenance – detect and prevent power quality issues before they cause downtime.
- Long-term analysis – uncover hard-to-find or intermittent issues. Load studies – verify electrical system capacity before adding loads.
Fluke 1742 Three-Phase Power Quality Loggers
Brand | FLUKE |
Model | Fluke - 1742 |
Size | 23 cm x 18 cm x 5.4 cm |
Maximum input voltage | 1000 Vrms, CF 1.7 |
Bandwidth | 42.5 Hz to 3.5 kHz |
Measurement category | 1000 V CAT III/600 V CAT IV |
Input impedance | 10 MOhm |
We are one of the leading wholesale traders of Fluke 1742 Three-Phase Power Quality Loggers.
Software Features
- "In-workshop" or "in-the-field" setup and download through PC application software: simple download using USB memory stick, WiFi download, the wired ethernet connection or via USB cable.
- Energy Analyze plus application software: Download and analyze every measured detail of energy consumption and power quality state-of-health with automated reporting.
- One-touch reporting: Create standardized reports according to commonly used standards like EN 50160, IEEE 519, GOST 33073 or export data in PQDIF or NeQual compatible format for use with the third-party software.
- Advanced analysis: Choose any available logged parameter to create a highly customized view of logged measurements for advanced correlation of data.
Hardware Features
- Measure all three voltage and current phases plus the neutral current: Three-phase and neutral voltage leads and four flexible current probes.
- Comprehensive logging: More than 20 separate logging sessions can be stored in the instrument. A comprehensive range of power and power quality variables are automatically logged so you never lose measurement trends.
- Measure with premium accuracy: Meets the rigorous IEC 61000-4-30 Class A Edition 3 standard for 'Testing and measurement techniques-Power quality measurement methods.'
- Capture dips, swells and interruptions: 1748 includes event waveform capture and RMS event profile, along with the date, timestamp and severity information to help pinpoint potential root causes of power quality issues.
- Measure key power quality parameters: Measures harmonics and interharmonics for voltage and current, also includes unbalance, flicker and rapid voltage changes.
- Optimized user interface: Capture the right data every time with quick, guided, graphical PC based application setup and reduce uncertainty about your connections with an intelligent verification feature and the only auto-correction function for a power quality logger. Connection errors are automatically indicated via an amber light on the units power button which turns green once corrected.
- Optimized user interface: Quick, guided, graphical setup ensures you're capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty
- Flexible power supply: Powers directly from the measured circuit with the widest available range for a power quality logger automatically going from 100 V to 500 V or from a wall line cord, so you can test anywhere.
- Rugged and reliable: Designed to withstand harsh installation environments with the IP65 rating when used with IP65 voltage input adapter.
- Two external USB ports: One for PC connection and another for quick, simple data download to standard USB thumb drives, or other USB devices, allowing you to leave the measurement device in place without disrupting logging.
- Ethernet connectivity: Wired and wireless connections for instrument setup and high-speed data download.
- Compact size: Designed to fit in tight spaces and panels with small (9.1 in x 7.1 in x 2.1 in) footprint.
- Highest safety rating in the industry: 600V CATIV/1000V CATIII rated for use at the service entrance and downstream.
- Optimized measurement accessories: Unique tangle-free flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces.
- Battery life: Four-hour operating time (backup time) per charge on a lithium-ion battery to withstand temporary power disruptions.
- Security:
- Magnetic hanger kit
Three Phase Power Recorder - Fluke 1750
Model | Fluke - 1750 |
Application | Industrial Use |
Brand | FLUKE |
Internal memory capacity for data | At least 2 GB |
Maximum recording period | At least 31 days |
Power requirements | 100 to 240 V rms +/-10%, 47-63 Hz, 40 W |
Dimension | 215 x 310 x 35 mm |
Mass | 6.3 kg |
PLL lock range | 42.5 to 69 Hz |
Applications
Long-term analysis: Uncover hard-to-find or intermittent issues; monitor critical equipment, capturing power quality events to correlate with equipment malfunction
Power quality surveys: Quantify power quality throughout a facility, documenting results with professional reports
Quality of service compliance: Validate incoming power quality at the service entrance
Equipment Installation/Commissioning: Benchmark: power system prior to installing to ensure a quality of service